defaultalt Technical University of Denmark
Field II Summer School on Advanced Ultrasound Imaging
    Main Page
Center for Fast
Ultrasound Imaging
Field II

Program

Menu Line
Registration
Menu Line
Prerequisites for participation
Menu Line

Lecture plan

Menu Line
Reading material
Menu Line

Lecturers and facilities

Menu Line

Exercises

Menu Line
   1: Field II beamforming
   2: SA data acquisition
   3: Velocity estimation
   4: Super resolution
   5: RC beamforming
   6: CMUT simulation
Menu Line
Groups and time plans
Menu Line

Assignments

Menu Line

Location and travel information

Menu Line
Accommodation
Menu Line
Organization
Menu Line

Social program

Menu Line

Photos Day 1

Menu Line
Photos Day 2
Menu Line
Photos Day 3
Menu Line
Photos Day 4
Menu Line
Photos Day 5
Menu Line
Photos Day 6
Menu Line
Photos presentations
Menu Line

Site

Menu Line


Acquiring data using the Vantage scanner and the CFU_scan program


Friday, May 25, 10.00-12.00 on the top floor in build 349, rooms 215 and 229.

Purpose:


The purpose of this exercise is to acquire ultrasound RF datasets from a wire phantom and from a tissue-mimicking phantom and beamform them.

Preparation:


Read the description of the CFU_scan program.

Exercise:


  1. While waiting for your turn to perform a test scan, develop your beamforming routine using the reference data set. The tims slots for the various groups can be found at: Groups.
  2. To extract emission data, use the function:
    [filtered_samples, t_start, rx_fs, elem_positions, vsrc_position, c] ...
                 = load_scan_data(path_data, frame_index, em_idx);
        
    where the output is:
      filtered_samples - RF data with matched filter applied; 
                         raw RF data can be obtained by modifying the function
      t_start - start time of the RF data
      rx_fs - sampling frequency of the recorded RF data
      elem_position - element positions [N x 3], containing X, Y and Z for 
                      every active element on the requested emission
      vsrc_position - position of the virtual source
      c - speed of sound in the phantom     
      
  3. Start CFU_scan, chose a scan location while in preview mode.



    Image for the wire phantom



    Image for the cyst phantom

  4. On the wire phantom: Acquire one frame and save it. Transfer it to the USB drive and then to your compute.

  5. On the tissue-mimicking phantom: Acquire 10 frames and save them. Transfer them to the USB drive and then to your compute.

  6. Beamform the images using the beamformation routine developed by you previously.

Equipment


2 stations, each consisting of:
  1. a Vantage scanner
  2. a linear transducer GE L3-12-D / L9-D
  3. a wire phantom
  4. a tissue-mimicking phantom

/jaj/aui_2023/exercises/exercise_2_data_acquisition/cfu_scan_exercise.html
Last updated: 18:03 on Wed, 24-May-2023